d | l1 | b1 | b2 | l2 | s | max. flow in l/min | max. permissible operating pressure in bar | ≈ necessary minimum flow volume Q in l/min Water | Hydraulic oil (HPL 22) |
Hydraulic oil (HPL 64) | max. pressure drop due to the flow indicator in bar |
---|---|---|---|---|---|---|---|---|---|---|---|
G 1/4 | 66 | 44 | 27 | 22 | 20 | 10 | 25 | 0.6 | 2.5 | 3.5 | 0.15 |
G 3/8 | 92 | 60 | 40 | 36 | 28 | 20 | 15 | 1.2 | 3 | 4 | 0.25 |
G 1/2 | 92 | 60 | 40 | 36 | 28 | 40 | 15 | 1.2 | 3 | 4 | 0.3 |
G 3/4 | 114 | 70 | 70 | 46 | 46 | 60 | 15 | 2.1 | 3.7 | 5 | 0.17 |
G 1 | 114 | 70 | 70 | 46 | 46 | 80 | 12 | 2.1 | 3.7 | 5 | 0.15 |